BioDiffuser® Chamber

Multiple sizes to meet a variety of design requirements

Built on decades of industry experience, this open bottom louvered sidewall leaching chamber product is offered in four sizes to meet your narrow and wide trench designs. These products are specifically designed to be the perfect solution for any gravity, pressure dosing or mound design. The product's unique post and dome joint configuration requires no screws for easy installation. Its universal end cap can be used for either end of your trench..

  • Lightweight easy to install
  • Stackable chambers are easy to transport
  • Open bottom area and slotted sidewall for effluent infiltration

Find a Rep

Product Information

Uniquely designed for trenches varying in width and length.

BioDiffuser® Chamber Specifications

1100BD 1600BD Bio2 Bio3
Length 76" (1.9 m) 76" (1.9 m) 87" (2.2 m) 87" (2.2 m)
Effective length 75" (1.9 m) 75" (1.9 m) 86" (2.2 m) 86" (2.2 m)
Sidewall Height 6.4" (16 cm) 9.7" (25 cm) 9" (23 cm) 9" (23 cm)
Overall Height 11" (28 cm) 14" (36 cm) 12" (30 cm) 12" (30 cm)
Overall Width 34" (86 cm) 34" (86 cm) 15" (38 cm) 22" (56 cm)
Capacity 9.2 CF 11.91 CF 5 CF 8.5 CF

Downloads

Submittal Packages

Drainage_Handbook_ADH1-Specifications 04-05-18

Installation Guides

Installation_Onsite_Leach_11in_Biodiffuser_Trench_(Detail_910A)
Installation_Onsite_Leach_Serial_11in_Biodiffuser_(Detail_911A_03-16)-Model
Installation_Onsite_Leach_At_Grade_11in_Biodiffuser_(Detail_0913A_04-16)-Model
Installation_Onsite_Leach_16in_Hi_Capacity_Biodiffuser_(Detail_910B_04-16)-Model
Installation_Onsite_Leach_16in_Hi_Capacity_Biodiffuser_Trench_(Detail_910B)
Installation_Onsite_Leach_At_Grade_16in_Hi_Capacity_Biodiffuser_(Detail_913B_04-16)-Model
Installation_Onsite_Leach_Grade_Arc_18_(Detail_908A_04-16)-Model
Installation_Onsite_Leach_Serial_Bio_2_Biodiffuser_(Detail_911C_04-16)-Model
Installation_Guide_Onsite_Leach_Bio_3_Bio_2_(Prod_Note_3_121_07-00)
Installation_NY_Onsite_Guide_Leach_Bio 3_(Prod_Note_3.121A_NYS)
Installation_Guide_Onsite_Leach_Biodiffuser_ Oregon_(Prod_Note_3.121_A-OR)
Installation_Onsite_Leach_Bio_2_Biodiffuser_(Detail_910C_04-16)-Model
Installation_Onsite_Leach_Bio_3_Biodiffuser_(Detail_910D_04-16)-Model
Installation_Onsite_Leach_Cluster_Bio_2_Biodiffuser_(Detail_912C_04-16)-Model
Installation_Onsite_Leach_Serial_Bio_3_Biodiffuser_(Detail_911D_04-16)-Model
Installation_Onsite_Leach_Cluster_Bio_3_Biodiffuser_(Detail_912D_04-16)-Model
Drainage_Handbook_ADH5_Installation_(11-16)

Specifications

Drainage_Handbook_ADH8_References_Standards_(06-14)

Details - Product

Biodifuser_High_Invert_(Detail_6036)
Onsite_Leach_Biodiffuser_(Product_Details_909A_04-16)-Model

Durability - Technical Literature

Chemical_Resistance_PP-Elastomers_(Tech_Note_A4.02)

Fittings

Fittings_Onsite_Leach_Misc
ADS_Fittings_Manual_-_09-16-16

Brochure

Brochure_Onsite_(10265_10-15)
Water Management Product Catalog 2018