SaniTite®HP - HP- PP Pipe

Gravity Flow Sanitary Sewer Pipe

SaniTite HP offers an alternative to choices currently not performing in our nation's gravity-flow-buried infrastructure. Featuring advanced polypropylene resin technology and an exclusive triple-wall design, SaniTite HP is the logical choice for gravity flow sanitary sewer pipe. SaniTite HP offers superior joint performance, chemical abrasion, impact resistance, and additional redundancies and factors of safety not received by comparable products. It is also manufactured with enhanced pipe stiffness, beam strength and joint integrity, for a long-lasting life. The bell and spigot joining system provides an added factor of safety for design engineers by including polymer-reinforced bells and double gasket spigots on every stick of pipe.

  • Increased stiffness yields an additional safety factor against construction loading and poor installations
  • The extended bell and spigot joint with redundant, double-gasketed joints meets ASTM D3212 and ensures lab and field testable watertight performance
  • 1,000 hour 10.8 psi (74.5 kPa) joint test for 30”-60” (750 mm - 1500 mm) pipe per ASTM F2764
  • Meets industry standards for manhole connections, testing and installation
  • Inert PP material is resistant to the effects of chemicals, abrasion, hot soils, and caustic effluent
  • Lightweight product for best installed cost for maximizing delivery and installation efficiencies
  • Readily available in convenient locations to service local projects

Find a Rep

Product Information

The SaniTite HP pipe is part of the already proven N-12 product line and has been specifically engineered for the gravity flow sanitary sewer market.

SaniTite HP Specifications

Diameters Available 12-60 inch (300 mm-1500mm)
Lengths Available 13, 16.3 & 20 feet (4.0m, 4.9m & 6.1m)*
Joint Performance Water Tight (ASTM D3212)
Joining System Extended Reinforced Integral Bell & Double Gasketed Spigot
Specifications ASTM F2764 (12-60 inch, 300 mm-1500mm)
Design Service Life Minimum 100 Year

*other lengths available, please contact your sales rep for more details

Downloads

Submittal Packages

Drainage_Handbook_ADH1-Specifications 04-05-18
Minimum_and_Maximum_Cover_Depths_for_12in-60in_SaniTite_HP_(Tech_Note_2.09_12-16)

Installation Guides

Drainage_Handbook_ADH7_Sanitary_Sewer_Systems_(03-16)
Installation_Guide_SaniTite_HP_Brochure_(10667_10-13)
Installation_Guide_SaniTite_HP_Pipe_Sanitary_(08-16)
Installation_Flowable_Fill_for_Thermoplastic_Pipe_(Tech_Note_A5.02)2
Installation_Guide_SaniTite_HP_MH_Adapter_(IG_1.06_07-14)
Installation_SaniTite_HP_12in_to_60in_Pipe_Trench_(Detail_101F_01-17)-Model
Installation_SaniTite_HP_Standard_Trench_(Detail_110)
Installation_SaniTite_HP_Tee_Base_w_Precast_Riser_(Detail_410_02-16)-Model
Installation_SaniTite_HP_Tee_Base_w_SaniTite_HP_Riser_Less_than_13ft_(Detail_408_02-16)-Model
Installation_SaniTite_HP_Tee_Base_w_SaniTite_HP_Riser_Less_than_20ft_(Detail_409_02-16)-Model
Recommended_Use_of_Trench_Boxes_(Tech_Note_A5.01)
SaniTite_HP_Pipe_Repair_Options_(Tech_Note_A5.13-ID_9738)
SaniTiti_HP_12_to_30_in_MH_Boot_and_Corr_Adapter_(Detail_205C)
SaniTite_HP_12_to_30_in_MH_Pre-Cast_Compression_Gasket_Detail_(205A)
SaniTite_HP_30_to_60_in_MH_Boot_Detail_(205E)
SaniTite_HP_30_to_60_in_MH_Pre-Cast_Compression_Gasket_Detail_(205B)
Soil_Classes_of_Embedment_and_Backfill_Materials_(Detail_109_01-16)-Model
Installation_Lining_of_Casings_Sanitite_HP_(Detail_110_01-16)-Model
Drainage_Handbook_ADH5_Installation_(11-16)

Specifications

Specification_ADS_SANITITE_HP_PIPE_12in_to_60in_2017
Specification_ADS_WATERSTOP_GASKET_12in_to_60in_2017
Drainage_Handbook_ADH8_References_Standards_(06-14)
33 42 11 Stormwater Gravity Piping Master CSI Spec Format 022318

Details - Product

SaniTite_HP_(Product_Detail_1300_01-17)-Model
Connection_Drop_Manhole_12in_to_24in_SaniTite_HP_(Detail_208_02-16)-Model
Connection_Drop_Manhole_30in_to_60in_SaniTite_HP_(Detail_209_02-16)-Model
Connection_MH_Grouted_12in_to_60in_HDPE_PP_(Detail_202_03-16)-Model
Connection_MH_Push-Thru_Manhole_30in_to_60in_SaniTite_HP_(Detail_205G_06-16)-Model
Connection_SaniTite_HP_to_Dissimiliar_Pipe_Connection(Detail_606_-Model
Connection_SaniTite_HP_to_RCP_w_MarMac(Detail_604B_02-16)-Model
Connection_Water_Tight_SaniTite_HP_to_RCP_w_MarMac_(Detail_604C_04-16)-Model
Connection_Water_Tight_MH_Boot_30in_to_60in_SaniTite_HP_(Detail_205E_01-16)-Model
Connection_Water_Tight_MH_Boot_and_Corr_Adapter_Gasket_12in_to_30in_SaniTite_(Detail_205C_01-16)-Model
Connection_Water_Tight_MH_Pre-Cast_Compression_Gasket_12in_to_24in_SaniTite_HP_(Detail_205A_06-16)-Model
Connection_Water_Tight_MH_Pre-Cast_Compression_Gasket_30in_to_60in_SaniTite_HP_(Detail_205B_01-16)-Model

Inspect. & Maintenance. - Technical Literature

Post_Installation_Testing_SaniTite_HP_(Tech_Note_A5.17_08-16)

Structural Design - Technical Literature

Drainage_Handbook_ADH2_Structures_(05-15)
Minimum and Maximum Cover Depths for 12in-60in SaniTite HP (Tech Note 2.09 12-16)

Hydraulics - Technical Literature

Drainage_Handbook_ADH3_Hydraulics_(07-14)

Durability - Technical Literature

Abrasion_Resistance_of_Polypropylene_(Tech_Note_A4.03)
Chemical_Resistance_PP-Elastomers_(Tech_Note_A4.02)
Greenbook_Pickle_Jar_Test_SaniTite_(AD110213)
Drainage_Handbook_ADH4_Durability_(11-15)

Fittings

Fittings_Sanitite_HP_Manual_(02-15)
Fittings_SaniTite_HP _12_to_30_in_MH_Boot_and_Fitting_Detail_(205D)

Case Studies/Approvals

Approval_NV_Clark_Co_Sanitite_HP
Article_Everything-About-Wateradding-sanitary-sewer_(11-14)-
Article_EAW_Adding_Sanitary_Sewer
Article_NY_Sanitite_HP_A_Beter_Replacement_(03-15)
Article_MN_Richfield_engineering_HP_SaniTite_(08-14)
Article_MI_Southgate_stems_sanitar_sewer_overflow_HP_Waterworld_(11-15)
Article_SaniTite_HP_Stormwater_(ADS_09-15)
PP_vs._RCP_Pipe_Comparison__12-16
Sanitary Sewer Pump Station Water & Waste Digest magazine January 2018

Brochure

Brochure_SaniTite_HP
Brochure_24in_to_60in_SaniTite_(10586_11-08)
Water Management Product Catalog 2018